For a complete descriptions of Transcat Service Levels, click here. Already have this this item and need calibration? Request a calibration quote. Sign up or Login Now! Questions about availability or need help? Contact Us: sales transcat. Add to Cart Add to Quote. Megger DLRO Digital Low Resistance OhmMeter. Print Email Save Item Compare.
Skip to the end of the images gallery. The instrument terminals will become live when connected to the circuit. Therefore when used on hazardous voltages custom Megger DH6 test leads must be used. Testing inductive circuits can be hazardous: After testing an inductive load there will be an amount of energy stored in the inductance. Both instruments provide a maximum test current of 10 Amps d.
This is a warning that the item under test is live and might be dangerous. This screen also provides access to the menuing system, through which you set up your instrument and choose the desired test parameters. Navigation of this menuing system is by means of the cursor control and Enter key. See both circuits are inadequate. Check the contacts, since a measurement Test Modes later in this manual for details of each mode. A copy of test result average must fall if it is to be signalled as a Pass a long tone AVO Download Manager, which facilitates downloading from the buzzer.
Select the desired option using the cursor control. This overrides the default setting under Options, Storage for one test only. If you wish to add comments to the test results, instead of pressing Enter, briefly press one of the twelve keys on the keypad. Page Unidirectional Mode Test Modes The time required for a stable reading may vary from a few seconds up to several minutes depending on the inductance and resistance of the test sample.
There is no time limit for the inductive mode test, which will continue until the operator presses the Test button. However, be used.
Remove the module by pressing on the raised circular in battery-management system that controls charging and monitors area of the retaining clips and pull the top of the clip away from the instrument body. There is a Flashing probably cause the battery to fail in less than 5 years.
This is available as an accessory, details can be found in the Accessories section of this user guide Rectify the error and repeat the measurement.
This unit is simply fitted to the instrument in place of the standard battery 7 Ah NiMH battery module. DH4 Duplex handspikes 2 , one with indicator lights. When in use a red LED is illuminated when 1. Page Repair And Warranty Approved Repair Companies A number of independent instrument repair companies have been approved for repair work on most Megger instruments, using genuine Megger spare parts. We want our customers to be fully satisfied with the goods they purchase from us, offering returns for up to 60 days.
Find out more about our refunds policy here. To speak to our sales team, call us on , use our Live Chat service or contact us online. For users who desire more control over the measurement process, the DLRO 10X uses a menu system controlled by a two-axis paddle to allow manual selection of the test current.
The DLRO10X Ductor is built into a strong, lightweight case that is equally at home in the field or in the laboratory. Light enough to be worn around the neck, they are small enough to be taken into areas which were previously too small to access.
Wind turbine lightning protection testing is made possible with the options of a 30m, 60m or a m extension reel. The m Megger KC Reel can be selected above, although for a full list of available test leads, please click here and contact us for a price and availability. Skip to the end of the images gallery.